Pendulum Impact Test Machine
Pendulum Impact Test Machine
- Safety Performance Test Equipment for Safety Glazing Materials Used in Buildings
- Pneumatic Tyres Device For Pendulum Test of Glass In Building According to BS EN 12600
- Test device for the impact performance of shot bag 45kg for Safety glazing materials in buildings
Classification
Pneumatic clamping shotbag impact testing machine
Manual shot bag impact testing machine
Samples adjustable Shot Bag Impact Tester
Data
Equipment dimensions: 1900mm×1500mm×3570mm
Sample size: 1930mm×864mm
Maximum impact height: 1200mm (customized)
Rubber pad: width 15mm, thickness 3mm, hardness Shore A50
Features
Impact test machine for toughened glass and laminated glass impact test
Standard
- AS/NZS 2208 Safety glazing materials in buildings – Appendix D: Impact Test
- GB 15763.3 Safety glazing materials in building Part 3: Laminated glass – Appendix C: Test device for the impact performance of shot bag
- ANSI Z97.1 Safety Glazing Materials Used in Buildings-Safety Performance Specifications and Methods of Test-Clause 5.1: Impact Test
- ASTM: E2353 Standard Test Methods for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades – Clause 7.3 Shot Bag, Traction and Release System
- BS EN 12600:2002 Glass in building – Pendulum test – Impact test method and classification for flat glass
Pneumatic Tyres Impactor
- Weight 50 kg ± 0.1 kg
- Tire pressure: 0.35Mpa ± 0.02Mpa
- Type: 3.50-R8 4PR

Shot bag
- Chinesel standard 45kg
- Australian standard 46kg
- Height: 330mm±13mm
Maximum diameter: 250mm
Material: lead shotgun in leather bag
Lead sand size: Φ2.5mm
Weight: 45kg±0.1kg 46kg±0.1kg

Pneumatic impact testing machine
- Raising method: electric
- Sample clamping method: pneumatic clamping
- Shotgun release method: automatic release



6: Inclined support 7: Cantilever 8: Elevation dial 9: Standing frame 10: Electric hoist
11: Switch cylinder 12: Shotgun impact body 13: Downward support
Manual impact testing machine
Raising method: manual
Sample clamping method: mechanical clamping
Release method: manual

Adjustable Impact Tester
The sample size can be adjusted, suitable for different sample testing

Force ball
Ball diameter: 76mm±1mm
Range: 30N
Accuracy: ±0.5%
Power: 3.7V lithium battery
Battery continuous use time: about 15 hours