ECE R43 Testing Equipment
Fragmentation test tools
- Mass: 75 g±0.3 g
- Radius of curvature of the point: 0.2 mm±0.05 mm
Mechanical strength test equipment according to ECE R43
Ball-impact test
- 227 g ball test
- 2,260 g ball test
Hardened steel ball:
- 2260g ± 20g, 82mm
- 227g ± 2g, 38 mm
Lift Device for steel ball
Height: 1 m, 3 m, 5 m, 12 m, customized
Support Fixture
Samples Applied Test Pieces Size: 300mm*300mm and 610mm *610mm
Release device
Electromagnetic
Headform test
Head-form Weight: 10kg
Head-form Size: 500mm932mm Impact height: < 1.5m Samples size: 1100mm500mm
Frame size: 1376mm670mm320mm
Test of resistance to high temperature
6: drain hole 7: Probe 8: Power distribution cabinet
9: Temperature control table 10: power switch 11: Distribution cabinet lock
Data:
- Power: 220V 50Hz 3Kw (Customized)
- Outside Size: 430mm*290mm*575 mm
- Inner Size: 400mm*255mm*480mm
- Rack:340mm*235mm*350mm
- At most 6 samples with 300mm*300mm
Scope:
- Determining the effect of exposure of safety glazing materials to temperature and humidity condition by boiling
Principle:
- Specimens are immerse in hot water and boiling water for specified period of time and inspect bubbles and others defects
Apparatus:
- The apparatus include two water baths, each of sufficient size to hold the test specimen fully immersed vertically on edge for the duration test.
Samples:
- Three specimen of size 300mm*300mm manufacture in a manner identical with impact test specimens and of like thickness shall be tested.
- These specimens may be cut from production samples of the size and thickness submitted for impact testing.
- For heat strengthened or toughened laminated glass, test specimen may be cut from a similar original sheet of annealed laminated glass
Procedure:
- Immerse the specimens vertically on edge in a bath of water maintained at a temperature of 66°C±3°C for 3 min
- Quickly transfer the specimens to a bath of water maintain at boiling point. Immerse the specimens vertically on edge for 2 h
- Remove the specimens and examine for the bubbles and others defects
Variou of testing equipment
Portable on-site Comprehensive Measurement Instrument for Energy-saving Glass
- It is applicable to the field test for opt thermal parameters of energy-saving glass installed and or to be installed
- The data that the instrument can measure is: thermal parameters, optical parameters, light transmittance, light reflectance, shading coefficient, U value, LSG, Low-E position, E value, space thickness, overall thickness, glass thickness
- The types of glass that the instrument can measure are:
- Single pane, Laminated glass, Uncoated insulated glass, Coating on both sides and below, Coating on more than two sides, Coating on both sides and below, Coating on more than two sides, Vacuum glazing
U Value Meter For IG
This instrument is suitable for single Low-E glass, double glazing or triple glazing glass which the number of Low-E side is less than two.
Ball Drop Test Device:
- Steel Ball 2260g/1040g/508g/227g
- Drop Height 1m-12m
- Samples: 300mm/610mm
Pummel Test Device:
- Hammer head diameter: 30mm
- Impact Distance: Adjustable
Shot Bag Impact Testing Frame:
- Shot Bag 45kg/46kg
- Automatic Release
- Electric Lifting
- Pneumatic Clamping
Head Form Test Device
- Head Weight: 10kg
- Head Size: 500mm*932mm
- Impact height: < 1.5m
- Samples size: 1100mm*500mm
- Felt hat: 90g/89mm/3mm
- Frame size: 1400mm*666mm*320mm
PV Load Test Equipment
- Size: 6425mm*2000mm*3490mm
- Samples: 1643mm*991mm~2009mm*1027mm (Customized)
- Source: Sandbag
- Load: 2400Pa 5400Pa 8100Pa 10000Pa (Customized)
Pneumatic Tyres Device
- Weight 50 kg ± 0.1 kg
- Tire pressure: 0.35Mpa ± 0.02Mpa
- Type: 3.50-R8 4PR
Forced Entry Resistant Glass Test Device
- Axe: 810mm Long
- Axe Quality: 1.80kg
- Sample size: 610mm*610mm
Insulating Glass Dew Point Meter
- Operating temperature: -80°C ~ 100°C
- Tube height: 300mm
- Tube diameter: 50mm
- Temperature resolution: 0.1 °C
Hard/Soft Pendulum Shock Test for Lifts
- Hard pendulum shock device
- Height: 330± 15mm
- Max diameter: 240±10mm
- Weight: 10kg ± 0.1kg
- Material: according to ISO standard
- Filler: 3.5mm + 0.25mm
- Soft pendulum shock device
- Height: 330mm ± 15mm
- Maximum diameter: 240mm±15mm
- Weight: 45kg ± 0.5kg
- Material: leather bag
- Filler: diameter 3.5mm ± 1mm lead sand
Laminated Glass High Temperature Test Oven
- Power: 220V 50Hz 3Kw (Customized)
- Outside Size: 400mm*255mm*480mm
- Inside Size: 400mm*255mm*480mm
- At most 6 samples with 300mm*300mm
Tempered Glass Flatness Measuring Instrument
- Measurement of arcuate form and wave form of toughened glass
- Resolution: 0.01mm
- Measuring Span: 300mm-12000 mm ( Customized)
Impactor for building Glass and Metal Guardrail
- Impact Steel ball
- Weight: 1040g ± 10g
- Dia: 63mm
Shot bag impactor
- Weight: 45kg ± 0.1kg
- Height: 330mm ± 13mm
- Max diameter: 250mm
- Material: leather bag filling lead shot
- Leather thickness: 0.15mm
- Lead sand size: 2.5mm
Hard and Soft Body Impactors for Opaque Wall Components
- Soft body:
- Weight: 50kg
- Dia: 400mm
- Conical canvas bag filles with 3mm glass sphere
- Hard Body:
- Steel Ball 0.5 kg/50mm
- Steel Ball 1 kg/62.5mm